Built by a maritime engineer · 14+ years in shipyards

MARITIME
INTELLIGENCE
ON DEMAND.

REX answers like an engineer who has stood in the engine room — with values, standards, and references. Not vibes.

No login required Documents stay private Free to use
👑REXMaritime AI
Online
Cable size for a 45 kW pump at 440 V, 3-phase?
Full-load current ≈ 74 A (0.8 PF, 92% eff). Per IEC 60092-352, select 3 × 25 mm² XLPE (rated 89 A, 45 °C ambient). Voltage drop ≈ 1.8% at 40 m — within the 6% limit.
REX answers with standards, not guesses
SOLASMARPOLISM CODEIEC 60092STCWMLC 2006DNVPARIS MOUCABLE SIZINGALARM DIAGNOSISSOLASMARPOLISM CODEIEC 60092STCWMLC 2006DNVPARIS MOUCABLE SIZINGALARM DIAGNOSIS
14+
Years Maritime Experience
6
Knowledge Domains
100%
Private — No Data Stored
24/7
Available, No Login
Capabilities

Everything a maritime professional needs

REX is not a general chatbot with a maritime prompt — it is trained on maritime knowledge, regulations, and real shipyard experience.

Ask REX Anything

Cable sizing, voltage drop, SOLAS chapters, ISM requirements, alarm codes — specific values and standard references, not generic answers.

> emergency generator blackout test procedure?
REX · SOLAS II-1/44: auto-start within 45 s of blackout, connect essential loads per sequence table, 18 attempts/3 sources rule for starting arrangements…
🧭

Maritime Domain Expert

MARPOL Annex VI limits, MLC 2006 crew rights, Port State Control patterns — knowledge no general AI can match.

Document Q&A

Upload a maintenance manual, class survey, or circular. Ask specific questions — answers come straight from your document.

Privacy by Design

PDF text is extracted in your browser. Your documents never leave your device. Only your typed question reaches REX.

👑

Try REX now — it's free.

No login. No setup. Just ask. →

Origin

Not built in a lab.
Built in a shipyard.

REX carries 14+ years of real shipyard engineering — electrical commissioning on live vessels, class surveys with IRS, BV and DNV, CNC production, and the paperwork that comes with all of it.

Meet the engineer behind REX →
Audience

Who uses REX?

Real questions from real maritime professionals.

Ship Officers
  • MARPOL Annex VI SOx limits in ECA zones
  • ISM Chapter 9 — accident reporting
  • STCW rest hour documentation
Marine Engineers
  • Cable sizing for 45 kW pump at 440 V
  • Wärtsilä alarm code diagnosis
  • Ballast water exchange procedures
Shipyard Teams
  • DNV cable penetration requirements
  • IEC 60092 current rating tables
  • CNC G-code for plate cutting
Surveyors & PSC
  • Paris MOU common deficiency list
  • ISM Code audit checklist
  • MARPOL Annex I — oily water separator standards
Workflow

How it works

No setup. No training. No account. Just ask.

01

Open REX

No account, no setup — go straight to the chat.

02

Ask your question

Type any maritime question in plain English or technical terms.

03

Get a precise answer

Specific values, standard references, and actionable guidance — every time.

👑

Ready to ask REX?

No account. No setup. Start with any maritime question right now.

Open REX Chat →